The MEDICREA Group (Alternext Paris: FR0004178572 - ALMED), a company
that specializes in the development of personalized implants produced
for a patient’s specific need in the treatment of spinal pathologies,
today announced the company has received 510(k) clearance from the U.S.
Food and Drug Administration (FDA) for UNiDTM, the world’s
first patient-specific spinal osteosynthesis rod.
The technology will be premiered at the 2014 North American Spine Society (NASS) Annual Meeting taking place on November 12-15 in San Francisco, CA at booth #2231. The first U.S. patient underwent surgery to have personalized UNiDTM rods implanted earlier today in New York.
The technology will be premiered at the 2014 North American Spine Society (NASS) Annual Meeting taking place on November 12-15 in San Francisco, CA at booth #2231. The first U.S. patient underwent surgery to have personalized UNiDTM rods implanted earlier today in New York.
“MEDICREA’s groundbreaking UNiDTM
patient-specific rods include the most current clinical data and
software development along with the latest in personalized production
and industrialization to revolutionize how spine surgery is performed.
UNiDTM rods provide surgeons a very precise surgical method, supporting better patient care and improved economic outcomes”.
UNiDTM features a user-friendly software tool to help
surgeons preoperatively plan their surgery and order customized,
industrially-produced rods to fit the specific spinal alignment needed
for each individual patient. UNiDTM eliminates the need to
manually contour a rod during surgery, providing surgeons with a
precisely aligned rod prior to surgery and reducing the amount of time
patients spend in the operating room, which directly impacts infection
rate and quality of recovery.
“Understanding and restoring sagittal alignment is key towards
providing better patient outcomes and preventing the need for
reoperations, a major factor in rising health care costs. By providing
rod customization, UNiDTM allows surgeons to precisely
execute their preoperative plan and frees them from the antiquated
technique of freehand bending, ensuring individual patients receive the
most accurate and effective treatment. Having a more precise,
personalized rod ready before even stepping foot in the operating room
is a game-changer for spine surgery,” said Frank J. Schwab, MD, a
renowned orthopedic surgeon and spinal deformity expert, who performed
the first customized UNiDTM rod surgery in the U.S. today.
The UNiDTM rod system, which has been successfully implanted in over 100 patients in Europe offers a real-time support team, the UNiDTM
Lab, that provides a seamless process by which surgeons preoperatively
analyze, design and order the patient-specific rod. The UNiDTM
plug in, proprietary to MEDICREA, is embedded into the Surgimap
software, and provides surgeons a quick and efficient option for
ordering patient-specific rods. After the planning process is complete,
the order is transferred to the UNiDTM Lab, which processes the request and industrially produces and labels the rod specifically for the patient.
“When we created Surgimap in 2008 our primary goal was to provide a
research tool for surgeons to plan, measure and review their results,”
said Virginie Lafage, PhD, Co-Founder of NEMARIS. “As we collected data
we noticed a startling trend: 62 percent of patient remained sagittally
malaligned after surgery . This was occurring not because of a lack of
skills, but because surgeons have not had the best tools at their
disposal. Our collaboration with MEDICREA is an important step forward
for spine surgery. Combining our core competency, our software platform,
with MEDICREA’s hardware solution was necessary to bring a cutting-edge
solution to surgeons and the patients they treat. It would not have
been possible without such collaboration.”
The UNiDTM customized rod offers numerous benefits to surgeons and patients undergoing spine surgery.
- The primary benefit of UNiDTM is it allows surgeons to plan and then execute their operating strategy without compromises or approximation errors.
Until now, surgeons had no alternative but to use a bending device, known as a French bender, supplied in all instrument kits to bend the rods manually. This manual rod-contouring process involves estimating the curve in a very empirical manner using pre-operative X-rays displayed on a wall in the operating room. Significant error and variability exist with that approach. With UNiDTM, surgeons can now be certain of implanting spinal fusion rods that are precisely adapted to the patient because UNiDTM rods are personalized and accurately curved using a design established by the surgeon during the pre-operative planning phase with the Surgimap / UNiD™ software.
Additional advantages of UNiDTM include:
- Surgeons can improve their success rate in terms of global sagittal patient alignment.
With the free UNiDTM
application in the Surgimap software, spine surgeons have access to the
most recent scientific data available on the parameters necessary to
determine and restore sagittal alignment for each patient.
- Surgeons can save time and be more efficient in the operating room.
By eliminating the manual bending of rods
during surgery, surgeons can significantly reduce operating time. This
is an additional benefit, since infection rates and the quality of a
patient’s recovery are directly linked to the duration of the surgical
procedure. As soon as the surgeon validates the rod’s design in the UNiDTM application, MEDICREA precisely manufactures the implantable rod and delivers it within 5 working days.
- Surgeons can reduce the risk of spinal implant failure.
The UNiDTM rods, customized for
each patient, are pre-contoured using a controllable and reproducible
industrial process. This eliminates the intraoperative use of a bending
device, which creates indentations, or notches, in the rod. Such notches
are an acknowledged cause of rods breaking postoperatively, which can
occur in patients – especially adults with severe spinal deformities
“MEDICREA’s groundbreaking UNiDTM patient-specific rods
include the most current clinical data and software development along
with the latest in personalized production and industrialization to
revolutionize how spine surgery is performed. UNiDTM rods
provide surgeons a very precise surgical method, supporting better
patient care and improved economic outcomes,” said Denys Sournac,
Founder, CEO and Chairman of MEDICREA and added “FDA approval of UNiDTM
is a major milestone for MEDICREA. We started working closely with the
FDA nearly 2 years ago on that strategic approval and this newly
obtained clearance marks the culmination of years of research and
surgery planning to bring a patient-specific spine implant to market, as
well as the beginning of a new exciting era in spine surgery.”
UNiDTM patient-specific rods are universal implants
available in two alloys (Titanium TA6V ELI/Cobalt Chromium) and two
diameters (5.5 mm/6 mm), that match global standards. UNiDTM naturally fits into the PASS LP® thoraco-lumbar fixation system, present in a worldwide market segment estimated at $3.6 billion. The PASS LP®
system is already used by numerous spine surgeons in 35 countries, and
notably in the United States where this product accounts for the
majority of MEDICREA USA Corporation’s sales. MEDICREA’s customized
spine implant platform also includes the UNiDTM anterior lumbar
interbody fusion (ALIF) spine cages created with a 3-D printer. With the
support of specific software and advanced imaging, the UNiDTM
ALIF customized cages made of Poly Ether Ketone Ketone (PEKK) exactly
reproduce the anatomic details of a patient’s vertebral endplates. The
world’s first spinal fusion surgery using the UNiD™ ALIF customized 3-D
printed spine cages was performed on May 28, 2014 in France.
UNiD is the first patient-specific device cleared to treat
degenerative spine conditions including scoliosis and other type of
deformities, which represent a $2 billion market opportunity in the U.S.
alone. According to the National Scoliosis Foundation, an estimated six
million people in the U.S. have scoliosis. Each year scoliosis patients
make more than 600,000 visits to private physician offices, and an
estimated 38,000 patients undergo spinal fusion surgery. Adult spinal
deformity surgery is likely to increase in frequency with as much as 32
percent of the adult population suffering from scoliosis and a
prevalence of 60 percent among the elderly. Hospital costs of adult
spinal deformity surgery can exceed $100,000 per patient. Revisions and
reoperations place a large financial burden on the health care system –
increasing the average cost of adult spinal deformity surgery by more
than 70 percent. The market for revision surgeries is growing at a
significant rate because of the number of corrections performed with
approximation errors and misalignment over the past 20 years.
MEDICREA will be hosting a symposium on November 12 from 6:00pm to
8:00pm at the Inter Continental San Francisco featuring guest speakers
including Virginie Lafage PhD, Dr. Schwab and renowned San Francisco
neurosurgeon Christopher Ames, MD. Topics to be discussed include
integration of science into clinical practice, open procedures and
osteotomy techniques in adult spinal deformity and the role of
patient-specific implants into improving patient outcomes.
Source : News-Medical , 12th Nov 2014
Source : News-Medical , 12th Nov 2014
No comments:
Post a Comment